- Compliant with EU Eco-design Minimum Efficiency Performance Standards (MEPS) in cooling
SEER 12/7° up to 7.6 and SPER 12/7° up to 9.3 - Twin-rotor screw compressor equipped with a high efficiency motor and a variable capacity valve that permits exact matching of the cooling capacity of the load
- Flooded multi-pipe heat exchangers designed for efficient heat exchange
- Electronic expansion device permitting operation at a lower condensing pressure and improved utilization of the evaporator heat exchange surface
- Economizer system with electronic expansion device for increased cooling capacity
AquaForce® - 30XW-PZE
Premium water-cooled screw liquid chiller using HFO R-1234ze refrigerant or R-515B
The 30XW-PZE liquid chillers are designed for industrial and commercial applications where installers, consultants and building owners require high performance and proven reliability.
- Designed to optimise energy use
- Designed for reliable operation
- Safe Design
- Easy and fast installation
- Minimized operating sound levels
- Supports emissions reduction goals
- Refrigerant :
- R-1234ze / R-515B
- Compressor :
- screw fixed-speed
- Nominal cooling capacity :
- 275-1,125 kW
- Efficiency :
- High
- Application :
- Office building, Hotel & Leisure, Healthcare, Industry, Education
Features & Benefits
- Silencers on the compressors discharge line
- Silencers on the economiser return line
- Acoustic insulation on the components that are most subjected to radiated noise
- Option 257 further reduces the global unit sound level
- Compact design
- Simplified electrical connections
- Simplified hydraulic connections
- Fast commissioning
- PUREtec™ R-1234ze refrigerant
- R-515B A1 refrigerant
- Leak-tight refrigerant circuit
- Features supporting overall unit performance
- Major components are selected and tested with R-1234ze and R-515B refrigerant to support reliable operation
- Industrial-type screw compressors with oversized bearings and motor cooled by suction gas
- Two independent refrigerant circuits
- Auto-adaptive control
- Extensive endurance tests
- Specific polyol ester oil qualified by Carrier for using with HFO-1234ze or R-515B selected to maintain reliable bearing lubrication
- Specific compressor gaskets compatible with HFO-1234ze or R-515B, tested and validated by Carrier
- New relief valves designed for operation with HFO-1234ze or R-515B
- Specific electrical box with increased tightness and integrated blower that maintains positive air pressure to help reduce ignition risk
- New control algorithms
- Specific documentation that contains all the installation, operation, maintenance and safety instructions
- Equipped with oversized roller bearings and oil pressure lubrication designed to support operation, even at maximum load
- Precise adjustment of the compressor cooling capacity
- If a fault occurs, the compressor does not switch off, but continues operation with a reduced capacity (unloaded mode)
- The silencer in the discharge line reduces discharge gas pulsations for quieter operation
- The condenser includes an oil separator that helps reduce the amount of oil circulating in the refrigerant circuit and redirects it to the compressor
Controls
- Intuitive and user-friendly, coloured, 4.3" interface
- 10 languages available
- Easy access to the controller box
- Password protection
- Night-modex
- Energy management
- Units with SmartVu™ control can be easily accessed from the internet, using a PC with an Ethernet connection. This makes remote control quick and easy and offers significant advantages for service operations
- Equipped with an RS485 serial port that offers multiple remote control, monitoring and diagnostic possibilities
- Communicates with other building management systems via optional communication gateways
- The following commands/visualizations are possible from remote connection:
- Condenser pumps control: a digital input allows verification of condenser water flow (the flow switch must be supplied by the installer)
- Start/Stop of the machine
- Dual set-point management through a dedicated contact is possible to activate a second set-point (example: unoccupied mode)
- Demand limit setting: to limit the maximum chiller capacity to a predefined value
- Operation visualization: Indication if the unit is operating or if it is in stand-by (no cooling load)
- Alarm visualization
Carrier meeting the challenge of efficiency and climate change with PUREtec™ range.
Four years after the first installation of a water-cooled screw chiller based on HFO refrigerant in Europe, Carrier’s AquaForce chiller units with PUREtec refrigerant have been installed in more than 500 projects throughout the region, in multiple applications such as industrial, data centers, district heating, and healthcare.