Contact Us English | UK
  1. Commercial
  2. Products
  3. Chillers & System Components
  4. Water-to-water chillers & heat pumps
  5. 30WI

Range

Cooling-only or heating-only models with water-cooled condenser.

Acoustic configuration:

  • a - STANDARD version
  • b - LOW NOISE version. Compressor casing
  • c - VERY LOW NOISE version. Casing with compressor sound insulation

Features and Benefits

  • SCROLL hermetic compressors
  • Chilled water evaporator with brazed plates
  • Hot water condenser with brazed plates
  • Electrical power and remote control cabinet:
    • 400V-3ph-50Hz general electrical power supply (+10%/-10%) + earth
    • Transformer fitted as standard on the machine for supplying the remote control circuit with 230V-1ph-50Hz
  • 30WI electronic control module
  • Machinery directive 2006/42/EC
  • Electromagnetic compatibility directive 2004/108/EC
  • EMC immunity and emissions EN 61800-3 'C3'
  • Low voltage directive 2006/95/EC
  • RoHS 2011/65/EU
  • Pressure equipment directive (PED) 97/23/EC
  • Machinery directive EN 60-204 -1
  • Compressors
    • Built-in electric motor cooled by intake gases
    • Motor protected by internal winding thermostat
    • Placed on anti-vibration mounts
  • Evaporator and condenser
    • Brazed plate exchanger.
    • Stainless steel plates (AISI 316)
    • Plate patterns optimised for high efficiency
    • Armaflex thermal insulation on evaporator
  • Refrigerating accessories
    • Dehumidifier filters with rechargeable cartridges
    • Hygroscopic sight glasses
    • Solenoid valves on refrigerant lines (700 V to 1,200 V models)
    • Electronic expansion valves
  • Control and safety instruments
    • High and low pressure sensors
    • High pressure safety valves
    • Water temperature control sensors
    • Evaporator frost protection sensor
    • Factory-assembled evaporator water flow controller
  • Electrical box
    • Main safety switch with handle on front
    • Control circuit transformer
    • Circuit breaker for compressor motor
    • Compressor motor switches
    • Wire numbering
    • Marking of the main electrical components

Controls

  • Regulation of the chilled or hot water temperature
  • Regulation of the water temperature based on the outdoor temperature (water law)
  • Regulation for low temperature energy storage
  • Second set-point management
  • Complete management of compressors with start-up sequence, metering and runtime balancing
  • Self-adjusting and proactive functions with adjustment of parameters on drift control
  • In-series staged capacity-reduction system on compressors based on cooling and heating demands
  • Management of compressor short cycle protection
  • Management of the machine operation limit according to outdoor temperature
  • Operating and fault status diagnostics
  • Management of a fault memory allowing a log of the last 20 incidents to be accessed, with operating readings taken when the fault occurs
  • Lead/lag management of the two machines in parallel with runtime balancing and automatic changeover if a fault occurs on one machine
  • Machine time schedule
  • Display and access to the operating parameters via a multilingual LCD screen with 4 lines of 24 characters
  • Automatic operation control
  • Set-point 1/set-point 2 selector
  • Heating/cooling mode selector
  • Set-point adjustable via 4-20 mA signal
  • Compressor load shedding
  • Water pump 1 and 2 control
  • Fault reporting

Options & Accessories

  • Low noise level
  • Very low noise level
  • Lon, J-Bus or BacNet gateway
  • Lead/lag operation
  • Soft Starter
  • Remote control unit
  • Electrical energy metre
  • Refrigerant leak detection
  • Phase monitor

Documents