Lambeth Palace – Cultural Heritage

Priceless Book Collection in New Lambeth Palace Library Protected by Carrier

Key benefits

  • Highly efficient solution – just four heat pumps cover all requirements instead of six chillers with four on cooling duties and two on heating.

Background

The current storage conditions for the archive are less than ideal, and the new purpose-built library has been designed to the highest architectural and environmental standards to ensure the fragile collection is conserved for future generations.

The building and its services are designed to protect the archives from changes in humidity, temperature, air pollution and flood risk. The environmental control solution was produced by Max Fordham.

The highly efficient heating and cooling solution, installed by East West Connect, includes four Carrier chillers, two of which are cooling-only units and the others heat pump-based chillers. The heat pumps provide heating by default, but can also be operated in reverse cycle mode to augment cooling when summer conditions require additional capacity.

“The Carrier plant provides this through intelligent communication between the cooling and heating sides of the system. If the cooling system is unable to deliver the required capacity – due to either extreme weather conditions or in the unlikely event of mechanical breakdown – the heat pump units can be operated in reverse to provide additional cooling to bridge the gap.”

Technologies

  • 2 x Carrier AquaSnap cooling-only chillers
  • 2 x Carrier AquaSnap heat pump chillers

Challenges and Solutions

Conditions for archive storage areas follow the recommendations of PD 5454, Guide for the Storage and Exhibition of Archival Materials, which requires a temperature of 8 degrees C during winter and 18 degrees in summer, with a Relative Humidity (RH) of 45%. These conditions will be maintained as far as possible using a passive approach; if they begin to drift outside pre-set limits, the HVAC equipment will be used to maintain temperatures and humidity levels.

Related References

Data Centres
Air-to-Water Chillers

Orange Data Centre Normandy

The Orange Data Centre in Val-de-Reuil, Normandy, represents a modern and energy-efficient infrastructure designed to ensure high reliability and data security.

Read more
Office Buildings
Air-to-Water Chillers

Buckingham Palace Road

111 Buckingham Palace Road gets 2.4MW of Carrier Chillers in Air Conditioning Upgrade

Read more
Hotel & Leisure
Air-to-Water Chillers

Hilton Metropole - Hotel

Carrier helps a central London hotel upgrade its HVAC (Heating, Ventilation and Air Conditioning) system quickly and seamlessly with an airlift delivery of two new AquaSnap® chillers

Read more
Data Centres
Air-to-Water Chillers

Data Center In Frankfurt

AquaForce® 30XF air-cooled screw chiller: the solution for the data center application, with integrated 100% free-cooling.

Read more
District Heating
Air-to-Water Heat Pumps
Water-to-Water Heat Pumps

Glasgow Bank Estate

Major district heating project for Glasgow Bank estate

Read more
Air-to-Water Chillers

Jones Food Company

Energy-efficient cooling and heating solution for world’s largest vertical farm

Read more