Data Center In Frankfurt

AquaForce® 30XF air-cooled screw chiller: the solution for the data center application, with integrated 100% free-cooling.

A brand-new Data Center site

We supported this brand new data center project, located in Frankfurt (Germany), by putting together the specifications needed to deliver HVAC equipment designed to cool the site while reducing both energy consumption and carbon footprint.

Our new AquaForce® 30XF air-cooled chiller, designed for Data Center, newly launched in Europe features with this specific application. This air-cooled chiller has dedicated features especially designed to guarantee efficiency.

Carrier provided 38 AquaForce® 30XF air-cooled chiller units. All up to 1795 KW working at 16.6°C on 24.4 °C chilled water at an outdoor temperature of 39°C. Units are able to provide and ensure:

  • High energy efficiency in both, partial and full load thanks to the frequency controlled. Also, chillers can be run in three different operating modes: pure compressor operation, pure free-cooling operation, combination of free cooling and compressor operation.
  • Service continuity & redundancy with the option able to restore the power after 190 seconds. Due to the sensible arrangement of the components and the use of the V-condensers, it is possible to build approximatively 1800 KW on an area of 16.7 x 2.3 m.
  • Energy savings, with the integrated free cooling function with an internal glycol circuit. On the customer side, there is no glycol in the system and the customer system is operated with pure water to obtain the best possible efficiency. The power factor is 0.98, i.e., almost 1, meaning nearly no energy is lost in the power grid.
  • Low noise level with the frequency controlled.
  • Built-in solution: in the main control cabinet, which contains all the components for regulating and controlling the chiller, electrical harmonic filters are installed in an extra compartment, for limiting the electrical harmonics to less than 5%. By reducing harmonic currents and contamination, the risk of malfunctions and problems is significantly reduced. Moreover, it helps reducing the absorption of reactive power, resulting in a longer service life.

As a truly global partner, Carrier is able to support its customers from A to Z: offering a wide range of solutions and optimising performance at every stage of the data center lifecycle. At Carrier, we’re here with specific solutions and expertise to help meet data center challenges with confidence.

Related References

Data Centres
Air-to-Water Chillers

Orange Data Centre Normandy

The Orange Data Centre in Val-de-Reuil, Normandy, represents a modern and energy-efficient infrastructure designed to ensure high reliability and data security.

Read more
Data Centres
Water-to-Water Heat Pumps

Bahnhof - Data Centre

Carrier's AdvanTE3 C engineers, a group of Experts in Efficiency and Environment, developed an innovative solution that turns the data center waste heat energy into a district heating energy source in Sweden.

Read more
Healthcare
Air-to-Water Chillers

Royal United Hospitals Bath

Carrier R-32 Chillers Selected for Major Cooling Upgrade at Royal United Hospitals Bath.

Read more
Office Buildings
Air-to-Water Chillers

Buckingham Palace Road

111 Buckingham Palace Road gets 2.4MW of Carrier Chillers in Air Conditioning Upgrade

Read more
Hotel & Leisure
Air-to-Water Chillers

Hilton Metropole - Hotel

Carrier helps a central London hotel upgrade its HVAC (Heating, Ventilation and Air Conditioning) system quickly and seamlessly with an airlift delivery of two new AquaSnap® chillers

Read more
Air-to-Water Chillers

Jones Food Company

Energy-efficient cooling and heating solution for world’s largest vertical farm

Read more